CRY442 Accelerometer, Triaxial, 100mv/g, ±50g pk, 0.5Hz to 5kHz

CRY442 Accelerometer, Triaxial, 100mv/g, ±50g pk, 0.5Hz to 5kHz

CRY442 is a miniature triaxial acceleration sensor with a side-end output of 1/4 - 28 (4-pin). It is installed on an object by an M5 bolt. It can be used to measure small movements in laboratory and scientific research, and can also be used to monitor the vibration state of industrial equipment online.

Equipped with armored shielded cables, the CRY442 provides precise measurements of vibration parameters such as acceleration, velocity, and displacement, even in environments with significant industrial or electrical interference.

  • Side 1/4-28 (4-pin) connector
  • Compact structure
  • Built-in IEPE preamplifier
  • Three-way output, Simultaneously measure X, Y, and Z directions
No items found.

Technical Specifications

No items found.
No items found.
Please choose a topic.
Dynamic Specification
Measuring Range (peak)
Measuring Range (peak)
±50g pk
Sensitivity (25℃)
Sensitivity (25℃)
100mV/g(160Hz)
Frequency Response
Frequency Response
0.5Hz to 5kHz(±1dB)
Transverse Sensitivity
Transverse Sensitivity
≤5%
Amplitude Non-linearity
Amplitude Non-linearity
±1%
Electrical Specification
Output Impedance
Output Impedance
<100Ω
Excitation Voltage
Excitation Voltage
18VDC to 28VDC (Constant Current Source)
Full Scale Output (peak)
Full Scale Output (peak)
±5V
Constant Current Source Current
Constant Current Source Current
2mA to 10mA
Noise
Noise
<50uV
Bias Voltage
Bias Voltage
9V to 13V
Environmental Specification
Maximum Shock Level
Maximum Shock Level
±1,000g
Operating Temperature
Operating Temperature
-40℃ to 120℃(-40℉ to 248℉ )
Physical Specification
Connector Type
Connector Type
Side 1/4-28 (4-pin)
Mounting Threads
Mounting Threads
10-32UNF(M5, Microdot)
Construction
Construction
Shear
Case Material
Case Material
304 Stainless Steel
Piezoelectric Materials
Piezoelectric Materials
PZT-5
Level of Protection
Level of Protection
IP65
Weight
Weight
18g

Download

Get in touch

Are you seeking more information about CRYSOUND's solutions or need a demo? Contact us via the form bleow and one of our sales or support engineers will connect with you.
3 Axes
Addition Plug-in
Microphone Array
Intrinsic Safe
Test Contents
Number of Channels
IEC 61672-1:2013 Class
Feature
Structure
Operation
Polarization
Size of Microphone
Contact Testing
Application