CRY446 Accelerometer, Triaxial, 10mv/g, ±500g pk, 1Hz to 5kHz

CRY446 Accelerometer, Triaxial, 10mv/g, ±500g pk, 1Hz to 5kHz

CRY446 is a miniature triaxial acceleration sensor with a side-end output of 1/4-28 (4-pin).It is installed on an object through an M3-to-M5 adapter bolt. It can be used to measure small movements in laboratory and scientific research, and can also be used to monitor the vibration state of industrial equipment online.

CRY446 can be equipped with armored shielded cables to measure vibration parameters such as acceleration, velocity, and displacement under strong interference conditions such as industrial and electric power.

  • Side 1/4-28 (4-pin)
  • Compact structure
  • Built-in IEPE preamplifier
  • Three-way output, Simultaneously measure X, Y, and Z directions
No items found.

Technical Specifications

No items found.
No items found.
Please choose a topic.
Dynamic Specification
Measuring Range (peak)
Measuring Range (peak)
±500g pk
Sensitivity (25℃)
Sensitivity (25℃)
10mV/g(160Hz)
Frequency Response
Frequency Response
1Hz to 5kHz(±1dB)
Transverse Sensitivity
Transverse Sensitivity
≤5%
Amplitude Non-linearity
Amplitude Non-linearity
±1%
Electrical Specification
Output Impedance
Output Impedance
<100 Ω
Excitation Voltage
Excitation Voltage
18VDC to 28VDC (Constant Current Source)
Full Scale Output (peak)
Full Scale Output (peak)
±5V
Constant Current Source Current
Constant Current Source Current
2mA to 10mA
Noise
Noise
<50μV
Bias Voltage
Bias Voltage
+9V to +13V
Environmental Specification
Maximum Shock Level
Maximum Shock Level
±2000 g
Operating Temperature
Operating Temperature
-40℃ to 120℃(-40℉ to 248℉ )
Physical Specification
Connector Type
Connector Type
1/4-28 (4-pin)
Mounting Threads
Mounting Threads
M3 to M5
Construction
Construction
Shear
Case Material
Case Material
304 Stainless Steel
Piezoelectric Materials
Piezoelectric Materials
PZT-5
Weight
Weight
12g
Level of Protection
Level of Protection
IP65

Download

Get in touch

Are you seeking more information about CRYSOUND's solutions or need a demo? Contact us via the form bleow and one of our sales or support engineers will connect with you.
3 Axes
Addition Plug-in
Microphone Array
Intrinsic Safe
Test Contents
Number of Channels
IEC 61672-1:2013 Class
Feature
Structure
Operation
Size of Microphone
Polarization
Contact Testing
Application